 TRX SERIES II GAS-FIRED CONDENSING BOILER: TRX085  
 85,000 BTU | Wall-Hung | 96% AFUE | ASME “H” Stamped 
 The TRX085 Series II is a high-efficiency residential condensing boiler engineered for superior comfort, energy savings, and long-lasting performance. Certified to ANSI Z21.13 / CSA 4.9 standards, the TRX085 is wall-mounted with zero clearance to combustibles and incorporates NTI’s advanced stainless-steel heat exchanger technology. Its sealed combustion design ensures quiet, safe operation in all conditions, while Wi-Fi enabled controls provide convenient monitoring and adjustment.
 
The TRX085 Series II is a high-efficiency residential condensing boiler engineered for superior comfort, energy savings, and long-lasting performance. Certified to ANSI Z21.13 / CSA 4.9 standards, the TRX085 is wall-mounted with zero clearance to combustibles and incorporates NTI’s advanced stainless-steel heat exchanger technology. Its sealed combustion design ensures quiet, safe operation in all conditions, while Wi-Fi enabled controls provide convenient monitoring and adjustment.
Energy Efficiency
 The TRX085 is designed to maximize energy performance while minimizing fuel consumption:
 
The TRX085 is designed to maximize energy performance while minimizing fuel consumption:

Reliable Function
 The TRX085 is built with premium-grade components to deliver safe and reliable operation:
 
The TRX085 is built with premium-grade components to deliver safe and reliable operation:

Convenience & Installation
 The TRX085 simplifies installation and maintenance:
 
The TRX085 simplifies installation and maintenance:
Warranty Coverage
 Backed by NTI’s industry-leading warranty, the TRX Series II offers extended coverage for both parts and heat exchanger, ensuring long-term peace of mind and reliable performance.
 
Backed by NTI’s industry-leading warranty, the TRX Series II offers extended coverage for both parts and heat exchanger, ensuring long-term peace of mind and reliable performance.
| Item | Parameter | 
|---|---|
| Product | TRX085 Series II | 
| Input Rating (CH) | 9.4 – 85 MBH | 
| Heating Capacity | 79 MBH | 
| Net AHRI Rating | 69 MBH | 
| AFUE | 96% | 
| Modulation Ratio | 9:1 | 
| Boiler Setpoint | 68–179°F (20–82°C) | 
| Ambient Operating Range | 33–104°F (0.6–40°C) | 
| Max Water Pressure (CH) | 55 psi | 
| Relief Valve | 30 psi | 
| Gas Supply Pressure (NG) | 3.5 – 10.5 in. W.C. | 
| Gas Supply Pressure (LP) | 8 – 13 in. W.C. | 
| Heat Exchanger | 441 Stainless Steel, Watertube | 
| Dimensions & Weight | |
| Height | 35.4 in. (900 mm) | 
| Width | 17.3 in. (440 mm) | 
| Depth | 15.6 in. (395 mm) | 
| Weight | 110 lb (50 kg) | 
NTI-TRX-Series-II-Brochure-Comp
NTI-TRX-Series-II-Brochure-Comp-FR
TRX Series II Installation and Operation Manual TRX085:110C:120:150C
TRX Series II Installation and Operation Manual TRX085:110C:120:150C-FR
TRX Series II Installation and Operation Manual TRX150:199:199C
TRX Series II Installation and Operation Manual TRX150:199:199C-FR.pdf
⚠️ If lockout errors occur frequently, contact a qualified service technician. For safety, the boiler allows only 5 resets within 15 minutes; a 6th attempt locks the unit until power is cycled.
Receive our latest updates about our products & promotions.
Thanks for subscribing!
This email has been registered!
| Product | SKU | Rating | Description | Collection | Availability | Product Type | Other Details | 
|---|