GREE, FLEXX CASED COIL, TXV, 60KBTU

SUBMITTAL DATA FLEXX CASED A COIL WITH 60KBTU: GCAT60H/NaA Enhanced Cooling Efficiency: The Flexx Cased A Coil...
Vendor: Gree
SKU: GCAT60H/NaA
Availability: Out Of Stock
Please login to see the price
Please login to see the price
Please hurry! Only 0 left in stock
10 customers are viewing this product

SUBMITTAL DATA FLEXX CASED A COIL WITH 60KBTU: GCAT60H/NaA

  • Enhanced Cooling Efficiency:

    The Flexx Cased A Coil with 60KBTU offers exceptional cooling efficiency, ensuring optimal comfort in your space. With its high-performance design, this coil maximizes heat transfer and airflow, providing efficient cooling performance.

  • Reliable Performance: Designed with precision and built to last, the Flexx Cased A Coil guarantees reliable performance. It is engineered with quality materials and advanced manufacturing techniques, ensuring durability and long-lasting operation.

  • Seamless Integration: The Flexx Cased A Coil with 60KBTU is designed for easy installation and seamless integration with your existing HVAC system. Its compact and versatile design allows for flexible installation options, making it suitable for various applications.

  • Energy Savings: This coil is designed to work in harmony with your cooling system, optimizing energy efficiency and reducing operating costs. By maximizing heat transfer, it helps your cooling system run more efficiently, resulting in potential energy savings over time.

INDOOR UNIT DATA
Power Supply 208-230V/1Ph/60 Hz VA C
Sound Pressure Level 51 dB(A)
Control Voltage 24 VA C
Rated Current Cooling 5 A
Rated Current Heating 5 A
MCA 8 A
MOCP 15 A
Electric Heater (Optional) 10, 15, 20 KW
Air Flow 1600 CFM
External Static Pressure (Up to) 1 In W.c.
Dehumidification 12.13 pt/hr
INDOOR A COIL
External Dimensions (W x H x D) 24 1/2 × 28 1/2 × 21 1/4
Net Weight/Gross Weight 95/110 lbs

Gree Error Codes

  • E1 - Compressor high pressure protection
  • E3 - Compressor low pressure protection
  • E4 - Compressor air discharge high-temperature protection
  • F2 - Condenser temperature sensor error
  • F3 - Outdoor ambient temperature sensor error
  • F4 - Discharge temperature sensor error
  • F6 - ODU tube temperature sensor error
  • EE - ODU memory chip error
  • H4 - Overload
  • H5 - IPM protection
  • H6 - DC fan error
  • H7 - Driver out-of-step protection
  • HC - Pfc protection
  • Lc - Startup failure
  • P0 - Driver reset protection
  • P5 - Over-current protection
  • P6 - Master control and driver communication error
  • P7 - Driver module sensor error
  • P8 - Driver module high temperature protection
  • PA - AC current protection
  • Pc - Driver current error
  • PL - Bus low-voltage protection
  • PH - Bus high-voltage protection
  • PU - Charge loop error
  • ee - Drive memory chip error
  • e1 - High pressure sensor error
  • C4 - ODU jumper cap error